Boiler Furnace Type
|
Babcock & Wilcox balanced draft, pulverized coal fired, once-through natural circulation boiler, horizontal opposed.
Power Rating: 753 MWe
|
|
Steaming Rate
|
Steam delivered: 5,320,000 lbm/Hour (670 kg/sec)
|
|
Steam Conditions
|
Steam temperature at superheater outlet: 1005 F (540.6 C)
Steam
pressure at superheater outlet: 2534 psig (17.47 MPa)
Steam
temperature at reheater outlet: (1005 F) 540.6 C
Steam
pressure at reheater outlet: 495 PSIG (3.4 MPa)
|
|
Efficiency
|
87.6%
|
|
Number of Burners
|
54 Dual Register Burners arranged in three rows of nine burners each on both the front and rear walls.
|
|
Pulverizer
|
6 Mills of type MPS-89GR
|
|
Coal Burning Rate
|
300 Tons/Hour
|
|
Air Heaters
|
One Primary and Two Secondary Ljungstrom
|
|
Primary Air Fans
|
Two centrifugal fans with variable inlet vane control.
|
|
Forced Draft Fans
|
Two centrifugal fans with variable inlet vane control
|
|
Induced Draft Fans
|
Four centrifugal fans with inlet damper control.
|
|
Recirculation Fans
|
One centrifugal fan with variable inlet vane control.
|
|
Flue Gas Temperature
|
261 F (127 C) at air heater outlet
|
Additional Systems in this PlantSim model include:
|